Show simple item record

dc.creatorSousa Santos, Vladimir
dc.creatorCabello Eras, Juan Jose
dc.creatorSagastume Gutierrez, Alexis
dc.creatorCabello Ulloa, Mario Javier
dc.date.accessioned2019-01-16T21:55:23Z
dc.date.available2019-01-16T21:55:23Z
dc.date.issued2018
dc.identifier.issn0957-0233
dc.identifier.urihttp://hdl.handle.net/11323/1988
dc.description.abstractDifferent methods have been developed to estimate the energy efficiency of induction motors. The accuracy of these methods vary with the load factor, the unbalanced voltage (UV) and harmonics. The feasibility of these methods for efficiency estimation in real-time were theoretically and experimentally assessed during the operation under different operational conditions (i.e. balanced sinusoidal voltage (BSV), harmonics, UV and harmonics with UV). Results show that for load factors over 80%, the air-gap method is applicable under any condition, while the slip method is only applicable under BSV or balanced harmonic voltage. Moreover, for load factors over 40%, the nameplate method is applicable under BSV. Other methods result in errors over 8% and optimization methods are not applicable for real-time monitoring. Electric systems generally operates with some degree of UV and harmonics, while induction motors mostly operate with load factors below 60%, limiting the use of these methods for real-time measurement.spa
dc.language.isoengspa
dc.publisherMeasurementspa
dc.rightsAtribución – No comercial – Compartir igualspa
dc.subjectEnergy efficiencyspa
dc.subjectHarmonicsspa
dc.subjectInduction motorsspa
dc.subjectReal-time monitoringspa
dc.subjectVoltage unbalancespa
dc.titleAssessment of the energy efficiency estimation methods on induction motors considering real-time monitoringspa
dc.typeArticlespa