• español
    • English
    • português (Brasil)
  • English 
    • español
    • English
    • português (Brasil)
  • Login

Repositorio CUC

  • Inicio
  • Colecciones
  • Navegar
    • Autores
    • Títulos
    • Fechas
    • Materias
    • Tipo de Material
  • Biblioteca
  • Información de interés
  • Comunities Comunities
  • Authors Authors
  • Titles Titles
  • Dates Dates
  • Subjects Subjects
  • Resource Type Resource Type
View Item 
  •   DSpace Home
  • Producción científica y académica
  • Revistas Científicas
  • View Item
  •   DSpace Home
  • Producción científica y académica
  • Revistas Científicas
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Cambiar vista

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsPrint ISSNResource TypeElectronic ISSNProgramThis CollectionBy Issue DateAuthorsTitlesSubjectsPrint ISSNResource TypeElectronic ISSNProgram

My Account

LoginRegister

Statistics

View Usage Statistics

Línea base para el monitoreo de salud estructural del puente Gómez Ortiz a partir de pruebas de vibración ambiental


Viviescas Jaimes, Alvaro
Carrillo, Julián
Vargas Carvajal, Laura Andrea

Artículo de revista

2018-01-01

Corporación Universidad de la Costa

https://doi.org/https://doi.org/10.17981/ingecuc.14.1.2018.05

0122-6517, 2382-4700 electrónico

2382-4700

Caracterización dinámicaBuscar en Repositorio UMECIT
Salud estructuralBuscar en Repositorio UMECIT
MonitoreoBuscar en Repositorio UMECIT
Vibración ambientalBuscar en Repositorio UMECIT
Puente viga cajónBuscar en Repositorio UMECIT
Ajuste del modelo numéricoBuscar en Repositorio UMECIT

Introducción: En los últimos años, en Colombia hay un crecimiento en la construcción de puentes de grandes luces, en especial tipo viga cajón. Por la importancia de estas estructuras en la infraestructura del país, surge la necesidad de monitorear su integridad estructural, analizar su comportamiento a través de su ciclo de vida, detectar cambios causados por posibles daños y establecer planes de mantenimiento. Este monitoreo se puede realizar a través de la caracterización de las propiedades dinámicas de la estructura. Objetivo: Este estudio presenta los resultados de la línea base para el monitoreo de la salud estructural del puente Gómez Ortiz. El artículo presenta y discute los resultados de la caracterización dinámica de la estructura y se describe el proceso de ajuste de un modelo numérico con base en los resultados experimentales. Metodología: La caracterización dinámica se realizó utilizando la técnica experimental con medición de vibraciones ambientales. Para el procesamiento de datos se utilizaron cuatro técnicas diferentes, tales como selección de picos (PP), descomposición en el dominio de la frecuencia (FDD), descomposición en el dominio de la frecuencia mejorada (EFDD) e identificación del sub-espacio estocástico (SSI). Resultados: En el estudio se obtuvo información experimental de las propiedades dinámicas del puente, tales como frecuencias fundamentales, modos de vibración y fracciones de amortiguamiento. Conclusiones: Los resultados demostraron que las cuatro técnicas arrojan resultados similares, excepto para las fracciones de amortiguamiento, confirmando la incertidumbre de las técnicas experimentales para definir este parámetro.
 
Introduction− The construction of long-span bridges, especially box girder type, has been increasing in recent years in Colombia. Due to the importance that these structures represent for the infrastructure of the coun-try, there is a need to monitor their structural integrity to analyze their behavior throughout their life cycle, de-tect changes caused by possible damages and establish maintenance plans. This monitoring can be carried out through the characterization of the dynamic properties of the structure.Objective−This study shows the results of the structural health monitoring baseline carried out in the Gómez Ortiz bridge. The dynamic characterization of the structure is performed and discussed, as well as the process of adjust-ing a numerical model based on the experimental results. Methodology−The dynamic characterization of the structure was carried out using the experimental tech-nique based on ambient vibration tests. Four different techniques were used to post-processing the data ob-tained in these tests such as Peak Picking (PP), Frequen-cy Domain Decomposition (FDD), Enhanced Frequency Domain Decomposition (EFDD), and the Stochastic Sub-space Identification (SSI). Results− Experimental information of the dynamic prop-erties of the bridge was obtained in the study, such as fun-damental frequencies, modal shapes, and damping ratios. Conclusions−The results of the study demonstrated that the four techniques show similar results, except for damping ratios, which confirms the uncertainty of the ex-perimental techniques to define this parameter.
 

http://hdl.handle.net/11323/2422

INGE CUC

  • Revistas Científicas [1282]

Descripción: Línea base para el monitoreo de salud estructural del puente Gómez Ortiz a partir de pruebas de vibración ambiental.pdf
Título: Línea base para el monitoreo de salud estructural del puente Gómez Ortiz a partir de pruebas de vibración ambiental.pdf
Tamaño: 1.684Mb

Unicordoba LogoPDFOpen AccessFLIPLEER EN FLIP

Show full item record

Cita

Cómo citar

Cómo citar

Miniatura

Thumbnail

Gestores Bibliográficos

Exportar a Bibtex

Exportar a RIS

Exportar a Excel

Buscar en google Schoolar

Buscar en microsoft academic

untranslated

Código QR

Envíos recientes

    No hay artículos recientes

HORARIOS DE ATENCIÓN AL USUARIO

LUNES A VIERNES 7:00 a.m a 7:00 p.m

SABADOS: 8:00 a.m a 6:00 p.m

DOMINGOS Y FESTIVOS NO HAY ATENCIÓN


Ubicados en el Bloque 2, Piso 1 y 2

Logo CUC

Contacto

Correo: biblioteca@cuc.edu.co

Telefono: 3362248

Barranquilla, Colombia

Calle 58 # 55-66 Barrio Modelo


Accesos


  • Bases de datos
  • Investigación
  • PQR
  • Catálogo bibliográfico
  • Publish or perish
  • Booklick
  • Libby
Todos los derechos reservados.

Sistema DSPACE - Metabiblioteca | logo