• español
    • English
    • português (Brasil)
  • English 
    • español
    • English
    • português (Brasil)
  • Login

Repositorio CUC

  • Inicio
  • Colecciones
  • Navegar
    • Autores
    • Títulos
    • Fechas
    • Materias
    • Tipo de Material
  • Biblioteca
  • Información de interés
  • Comunities Comunities
  • Authors Authors
  • Titles Titles
  • Dates Dates
  • Subjects Subjects
  • Resource Type Resource Type
View Item 
  •   DSpace Home
  • Producción científica y académica
  • Revistas Científicas
  • View Item
  •   DSpace Home
  • Producción científica y académica
  • Revistas Científicas
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Cambiar vista

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsPrint ISSNResource TypeElectronic ISSNProgramThis CollectionBy Issue DateAuthorsTitlesSubjectsPrint ISSNResource TypeElectronic ISSNProgram

My Account

LoginRegister

Statistics

View Usage Statistics

Análisis de falla operacional de un sistema hidroneumático en instalación hospitalaria


Monteagudo Yanes, José Pedro
Jiménez Borges, Reinier

Artículo de revista

2018-08-27

Corporación Universidad de la Costa

https://doi.org/https://doi.org/10.17981/ingecuc.14.1.2018.14

0122-6517, 2382-4700 electrónico

2382-4700

NPSHdBuscar en Repositorio UMECIT
NPSHrBuscar en Repositorio UMECIT
CavitaciónBuscar en Repositorio UMECIT
BombeoBuscar en Repositorio UMECIT
CargaBuscar en Repositorio UMECIT
SucciónBuscar en Repositorio UMECIT

Introducción: El trabajo presenta el estudio de la falla operacional de un sistema hidroneumático destinado al suministro de agua a una institución hospitalaria. Objetivo: Determinar la o las causas de interrupción del suministro de agua del sistema hidroneumático a la edificación. Metodología: Se trazó la característica hidráulica del sistema de tubería y se comparó con la característica hidráulica del sistema hidroneumático, comprobando que satisfacía plenamente las solicitudes de carga y flujo requeridas por la edificación. Dada la presencia de ruidos y vibraciones en la tubería de succión se realizó la comparación del NPSH requerido con el NPSH disponible, determinando que el actual diseño de la tubería de succión es la causa de la falla del sistema hidroneumático. Resultados: Se proponen tres variantes de modificación al diseño de la tubería de succión que eliminan el fenómeno de la cavitación. Ello evita poner en operación una bombea auxiliar que incrementa el consumo energético en 8760 kWh/año con un costo de 1839,6 $/año y la inseguridad en el servicio de agua. Conclusiones: El equipo hidropresor seleccionado cumple satisfactoriamente los requerimientos de la instalación, exceptuando el diseño de la tubería de succión donde el NPSH disponible es inferior al NPSH requerido para caudales superiores a 900 l/min, apareciendo el fenómeno de la cavitación y provocando la salida de servicio del sistema.
 
Introduction− This paper presents the study of the operational failure of a hydro-pneumatic system for the supply of water to a hospital facility.Objective−Determine the cause or causes for the in-terruption of the water supply of the hydro-pneumatic system to the building.Methodology−The hydraulic characteristic of the pipe system was drawn and compared with the hydraulic characteristic of the hydro-pneumatic system, verify-ing that it fully satisfied the load and flow requests demanded by the building. Given the presence of noises and vibrations in the suction pipe, the comparison of the required NPSH vs. the available NPSH determined that the current design of the suction pipe is the cause for the hydro-pneumatic system failure.Results− Three variants for the modification of the design of the suction pipe in order to eliminate the phe-nomenon of cavitation are proposed. This avoids putting into operation an auxiliary pump that increases energy consumption by 8,760 kWh/year with a cost of 1,839.6 $/year and the insecurity in the water service.Conclusions−The selected hydro-pneumatic equip-ment satisfactorily meets the requirements of the instal-lation, except for the design of the suction pipe where the available NPSH is lower than the NPSH required at flow rates higher than 900 l/min, hence, producing the cavitation phenomenon and causing the output of system’s service.
 

http://hdl.handle.net/11323/2437

INGE CUC

  • Revistas Científicas [1282]

Descripción: Análisis de falla operacional de un sistema hidroneumático en instalación hospitalaria.pdf
Título: Análisis de falla operacional de un sistema hidroneumático en instalación hospitalaria.pdf
Tamaño: 655.4Kb

Unicordoba LogoPDFOpen AccessFLIPLEER EN FLIP

Show full item record

Cita

Cómo citar

Cómo citar

Miniatura

Thumbnail

Gestores Bibliográficos

Exportar a Bibtex

Exportar a RIS

Exportar a Excel

Buscar en google Schoolar

Buscar en microsoft academic

untranslated

Código QR

Envíos recientes

    No hay artículos recientes

HORARIOS DE ATENCIÓN AL USUARIO

LUNES A VIERNES 7:00 a.m a 7:00 p.m

SABADOS: 8:00 a.m a 6:00 p.m

DOMINGOS Y FESTIVOS NO HAY ATENCIÓN


Ubicados en el Bloque 2, Piso 1 y 2

Logo CUC

Contacto

Correo: biblioteca@cuc.edu.co

Telefono: 3362248

Barranquilla, Colombia

Calle 58 # 55-66 Barrio Modelo


Accesos


  • Bases de datos
  • Investigación
  • PQR
  • Catálogo bibliográfico
  • Publish or perish
  • Booklick
  • Libby
Todos los derechos reservados.

Sistema DSPACE - Metabiblioteca | logo