• Index page
  • Información de interés
  • Login
  • Communities & Collections
  • Language
    Englishespañolportuguês (Brasil)
View Item 
  •   Redicuc Home
  • Producción científica y académica
  • Revistas Científicas
  • View Item
  •   Redicuc Home
  • Producción científica y académica
  • Revistas Científicas
  • View Item
Universidad de la Costa, CUC. Calle 58 # 55 - 66. Barranquilla, Colombia. 336 22 00. repositorioredicuc@cuc.edu.co. Corporación Universidad de la Costa.

Control robusto de oscilaciones en sistemas de potencia mediante señales remotas

Thumbnail
View/Open
Control robusto de oscilaciones en sistemas de potencia mediante señales remotas (792.0Kb)
Date
2016-10-18
Author
González Ocampo, Diego
Loaiza, Alejandro
Arias Hernández, Alexander
Metadata
Show full item record
BASE GoogleScholar
Compartir:


Impacto

URI: http://hdl.handle.net/11323/2508
Citar con DOI: https://doi.org/10.17981/ingecuc.12.2.2016.06

Abstract

Este artículo presenta una estrategia de control robusto que hace uso de Power System Stabilizers (PSS’s) para enfrentar el problema de las oscilaciones inter-área en Sistemas Eléctricos de Potencia. La propuesta se fundamenta en la estrategia Δω planteada por Kundur y adecuada para tener en cuenta mediciones remotas de todas las máquinas generadoras del sistema de potencia. El Centro de Control calcula una señal de control para cada generador del sistema ponderando las mediciones de cada generador activo. La robustez de la propuesta permite afrontar el problema de los retardos que se presentan en las señales de comunicaciones debido a las mediciones remotas. La fortaleza de la propuesta se evidencia mediante su implementación sobre el sistema de prueba de 2 áreas y 4 máquinas de Kundur donde se consideraron los modelos completos de las máquinas. Se logró amortiguar de manera satisfactoria las oscilaciones que surgen después de implementar una falla trifásica a tierra, también se manejó adecuadamente el retardo en las señales de comunicación las cuales agregan inestabilidad al lazo cerrado.
 
This paper shows a robust control strat-egy to address the inter-area oscillations in power systems using PSS’s. The approach is based on the well-known ∆ω strategy of Kundur, and it was modi-fied to take into account remote signals of the whole power system. The control center computes control signals for each generator in the system weighting the different measurements of each active genera-tor. The robustness of the approach allows to face the communications delays due to remote measures. The strength of the proposed technique is validated through simulations over the Kundur two-area-four-machines test case power system, here it was used the complete model for the generators. The inter-area os-cillations after a three-phase fault were successfully damped; also, the latencies which add instability in closed loop were faced.
 
Para citar este documento con norma APA sexta edición utilice:
Ocampo, D., Loaiza, A., & Arias Hernández, A. (2016). Control robusto de oscilaciones en sistemas de potencia mediante señales remotas. INGE CUC, 12(2), 58-67. https://doi.org/10.17981/ingecuc.12.2.2016.06

Collections
  • Revistas Científicas

Browse

All of RedicucCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Compartir en

Universidad de la Costa, CUC

  • Calle 58 # 55 - 66. Barranquilla, Colombia

  • 336 22 00

  • repositorioredicuc@cuc.edu.co

Corporación Universidad de la Costa CUC, Personería Jurídica con Resolución No. 352 del 23 de abril de 1971 y reconocida como Universidad mediante resolución 3235 del 28 de marzo de 2012 expedida por el MEN. Institución de Educación Superior sujeta a inspección y vigilancia por el Ministerio de Educación Nacional.

Enlaces institucionales:

  • Universidad de la Costa
  • Biblioteca
  • Catálogo bibliográfico
  • Recuperador Primo

Universidad de la Costa CUC.
Politica de Protección de Datos.