Mostrar el registro sencillo del ítem

dc.contributor.advisorNúñez Blanco, Yuleisy Paolaspa
dc.contributor.advisorSchneider, Ismael Luísspa
dc.contributor.authorBarraza Villareal, Camila Andreaspa
dc.contributor.authorSánchez Quintero, Leidy Maríaspa
dc.date.accessioned2019-10-29T19:20:58Z
dc.date.available2019-10-29T19:20:58Z
dc.date.issued2019
dc.identifier.urihttp://hdl.handle.net/11323/5548spa
dc.description.abstractAir pollution is one of the most important environmental problems due to increasing urbanization. One of the pollutants that most affect air quality is atmospheric particulate material. This comes from multiple sources such as vehicular traffic, industrial emissions and indiscriminate burning, among others. In this way, the North-Historic Center of Barranquilla, due to its location, is susceptible to air quality deterioration since it receives the contribution of these sources, making it necessary to monitor the concentrations of these pollutants. In this study, PM10 levels were evaluated using two methodologies in the North-Historic Center of Barranquilla between April and October of 2018. Concentrations were determined using the gravimetric method with a low-cost Stacked Filter Unit (SFU) sampler and the Partisol equipment, validated by the United States Environmental Protection Agency (EPA). The results obtained by these two methodologies were compared using different statistical analyzes. Likewise, the influence of meteorological parameters on PM10 concentrations and the contribution of long-distance transport of this pollutant were evaluated. The results showed an average PM10 concentration of 46.40 µg/m3, respecting the Air Quality standards for Colombia. The sampler showed an efficiency of 98.26% in the collection of PM10. It was also shown that meteorological variables directly influence PM10 concentrations. The reliability of the low cost SFU sampler for continuous monitoring of this important air pollutant was demonstrated.spa
dc.description.abstractLa contaminación del aire es uno de los problemas ambientales más importantes debido a la creciente urbanización. De los contaminantes que más afectan a la calidad del aire está el material particulado atmosférico. Este proviene de múltiples fuentes como el tráfico vehicular, emisiones industriales y quemas indiscriminadas, entre otras. De esta forma, la zona Centro Norte – Histórico de Barranquilla, por su ubicación, es susceptible al deterioro en la calidad del aire ya que recibe el aporte de estas fuentes, haciendo necesario el seguimiento de las concentraciones de estos contaminantes. En este estudio fueron evaluados los niveles de PM10 mediante dos metodologías en la Región Norte-Centro Histórico de Barranquilla entre abril y octubre del año 2018. Las concentraciones fueron determinadas empleando el método gravimétrico con un muestreador de bajo costo Stacked Filter Unit (SFU) y el equipo Partisol, validado por la Agencia de Protección Ambiental de Estados Unidos (EPA). Los resultados obtenidos por estas dos metodologías fueran comparados utilizando diferentes análisis estadísticos. Igualmente fue evaluada la influencia de los parámetros meteorológicos en las concentraciones de PM10 y la contribución del transporte a larga distancia de este contaminante. Los resultados arrojaron una concentración promedio de PM10 de 46,40 µg/m3, respetando los estándares de Calidad de Aire para Colombia. El muestreador presentó una eficiencia de 98,26% en la recolección de PM10. Igualmente se evidenció que las variables meteorológicas influyen directamente en las concentraciones de PM10. Quedó demostrada la confiabilidad del muestreador de bajo costo SFU para el monitoreo continuo de este importante contaminante atmosférico.spa
dc.language.isospa
dc.publisherUniversidad de la Costaspa
dc.rightsAttribution-NonCommercial-ShareAlike 4.0 Internationalspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/spa
dc.subjectAtmospheric pollutantsspa
dc.subjectParticulate materialspa
dc.subjectPM10spa
dc.subjectMeteorological variablesspa
dc.subjectLong distance transportspa
dc.subjectContaminantes atmosféricosspa
dc.subjectMaterial particuladospa
dc.subjectVariables meteorológicasspa
dc.subjectTransporte a larga distanciaspa
dc.titleEvaluación de la concentración de material particulado pm10 en la Región Norte – Centro Histórico de la ciudad de Barranquilla.spa
dc.typeTrabajo de grado - Pregradospa
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.identifier.instnameCorporación Universidad de la Costaspa
dc.identifier.reponameREDICUC - Repositorio CUCspa
dc.identifier.repourlhttps://repositorio.cuc.edu.co/spa
dc.publisher.programIngeniería Ambientalspa
dc.relation.referencesAdriano Villa, E. del rocio. (2016). Sistema de extracción de material particulado en la construcción del hospital regional docente Ambato. (Universidad nacional de chimborazo). Retrieved from http://dspace.unach.edu.ec/handle/51000/3115 Alvarado Zuñiga, G. M. (2010). Estudio integrado de factores que influyen sobre la contaminación atmosférica por material particulado respirable de pudahuel (Universidad de Chile). Retrieved from http://mgpa.forestaluchile.cl/Tesis/Alvarado, Gerardo.pdf Amdur, M. O. (1969). Toxicologic Appraisal of Particulate Matter, Oxides of Sulfur, and Sulfuric Acid. Journal of the Air Pollution Control Association, 19(9), 638–646. https://doi.org/10.1080/00022470.1969.10466535 Angulo, R. (2008). Medición y Evaluación de la calidad del aire en los sectores de Fertisa y Trinitaria de la ciudad de Guayaquil debido a la presencia de material particulado menor a 10 y 2.5 um. Escuela Superior Politécnica del Litoral. Guayaquil, EC. Arciniegas, C. (2012). Diagnóstico y control de material particulado: partículas suspendidas totales y fracción respirable PM10. Revista Luna Azul, 34, 195-213. Arrieta Fuentes, A. J. (2016). Dispersión de material particulado (pm10), con interrelación de factores meteorológicos y topográficos. Ingeniería Investigación y Desarrollo, 16(2). https://doi.org/10.19053/1900771x.v16.n2.2016.5445 Artiñano, B., Salvador, P., Alonso, D ., Querol, X., y Alastuey, A. (2003). Anthropogenic and natural influence on the PM10 and PM2.5 aerosol in Madrid (Spain). Analysis of high concentration episodes. Environmental Pollution, 125 , 453-465. Bayas Guerrero, K. A. (2017). “Distribución espacial y multitemporal de material particulado, en los Campus Universitarios de la Unach de la ciudad de Riobamba.” In (Bachelor’s thesis, Universidad Nacional de Chimborazo, 2017). Retrieved from http://dspace.unach.edu.ec/handle/51000/4117 Bedoya, J., & Martínez, E. (2009). Antioquia-Colombia air quality in the aburrá valley Antioquia-Colombia. Año, 76, 7–15. Brusseau, M., Matthias, A., Comrie, A., & Musil, S. (2019). Ciencias Ambientales y de la Contaminación. Academic Press Calua Carrasco, C. E. R. (2018). Concentración de contaminantes sólidos sedimentables para el periodo mayo - junio 2017 en el entorno de la upn y su relación con las normas de la oms (Universidad Privada del Norte). Retrieved from http://refi.upnorte.edu.pe/bitstream/handle/11537/14073/Calua Carrasco Carlos Elder Rudecindo.pdf?sequence=1&isAllowed=y Chen, B., Stein, A. F., Maldonado, P. G., Sánchez de la Campa, A. M., González-Castanedo, Y., Castell, N., & de la Rosa, J. D. (2013). Size distribution and concentrations of heavy metals in atmospheric aerosols originating from industrial emissions as predicted by the HYSPLIT model. Atmospheric Environment, 71, 234–244. https://doi.org/10.1016/j.atmosenv.2013.02.013 Candanoza, S., Goribar, L., & García, F. (2013). Relación Particulas Respirables (Pm)/Partículas Suspendidas Totales (Pst) En Santa Marta (Colombia) 10. Dyna, 80(179), 157-164. Contreras Carrillo, E. (2012). Evaluación de los efectos en salud relacionados con la contaminación del aire para el sector ciudadela norte de la ciudad de Ocaña, norte de Santander (Universidad Francisco de Paula Santander Ocaña). Retrieved from http://repositorio.ufpso.edu.co:8080/dspaceufpso/bitstream/123456789/1140/1/28724.pdf Corte, D., Sierra, F., & Valencia, G. (2015). Validación del modelo matemático “Función de densidad de probabilidad (pdf) de Weibull”, evaluando el recurso eólico en la zona del caribe colombiano: caso estudio. Prospectiva. https://doi.org/10.15665/rp.v13i2.485 Cuesta, O. et al., (2014) Diagnóstico del medio ambiente atmosférico producto de las principales fuentes fijas de la Ciudad de la Habana. Informe científico técnico. INSMET. La Habana, Cuba. 192pp. Doria Oviedo, R., & Porras Barrios, T. (2017a). Distribución Temporal de la Fracción Respirable PM10 y la Correlación con las Variables meteorológicas en la universidad de la costa CUC (Universidad de la costa CUC). Retrieved from file:///C:/Users/compaq/Downloads/Distribucion temporal de la fracción respirable pm 10 y la correlación con las variables meteorológicas en la universidad de la costa CUC.pdf Durán Lombana, J. J., & Moscoso Culma, L. A. (2018). Análisis correlacional de datos de MP10 y partículas sedimentables, su composición fisicoquímica y mineralógica, en la zona norte de la ciudad de Bogotá. Retrieved from http://repository.lasalle.edu.co/handle/10185/28369#.XJQ1HSugwyI.mendeley Echeverri Londoño, C. A., & Maya Vasco, G. J. (2008). Relación Entre las partículas finas (pm2.5) y respirables (pm10) en la ciudad de Medellín (Vol. 12). EPA of the United States. Integrated Science Assessment (ISA) for Particulate Matter (Final Report, December 2009). United States Environmental Protection Agency, Washington, DC, EPA / 600 / R-08 / 139F, 2009.Estévez García, J. A. (2010). Exposición laboral a contaminación atmosférica: material particulado y efectos respiratorios en la salud de policías de tránsito de Bogotá, Colombia 2008-2009 (Universidad Nacional de Colombia). Retrieved from http://bdigital.unal.edu.co/2662/1/597591.2010.pdf Ezeh, GC, Obioh, IB, Asubiojo, OI y Abiye, OE (2012). PIXE characterization of PM10 and PM2. 5 particle sizes collected in Ikoyi Lagos, Nigeria. Toxicological & Environmental Chemistry , 94 (5), 884-894. Fuentes, A. (2016). interrelation of meteorological and topographic factors (Particulate Matter Dispersion ( PM 10 ), with interrelation of topographic and meteorological factors ). 16, 43–54. García Lozada, H. M. (2006a). Tipologia de las fuentes de emisiones de particulas. In Evaluación del riesgo por emisiones de partículas en fuentes estacionarias de combustión. Estudio de caso: Bogotá (p. 4). Retrieved fromhttps://books.google.com.co/books?id=T87uEuVP84kC&dq=fuentes+naturales+y+a ntropogenicas+de+material+particulado&hl=es&source=gbs_navlinks_s García Lozada, H. M. (2006b). Tipologias de las fuentes de emision de particulas. In Evaluación del riesgo por emisiones de partículas en fuentes estacionarias de combustión. Estudio de caso: Bogotá (p. 7). Retrieved from https://books.google.com.co/books?id=T87uEuVP84kC&printsec=frontcover&hl=es#v= onepage&q&f=false García R, F. F., Agudelo G, R. A., & Jiménez J, K. M. (2006). Distribución espacial y temporal de la concentración de material particulado en Santa Marta, Colombia. Rev. Fac. Nac. Salud Pública, 24(2), 73–82. Garrillo, E. (2010). Evolución y tendencia espacio -temporal de las concentraciones de material particulado pm10 considerando la influencia de los parámetros meteorológicos. Gómez Parada, L. A. (2001). Comportamiento espacial y Temporal de los Contaminantes Atmosféricos Medidos por la Red de Monitoreo de Calidad del Aire de Santiago (Universidad de Chile). https://doi.org/10.13140/RG.2.2.10638.15688 Harber, P., Barnhart, S., Boehlecke, B., Beckett, W., Gerrity, T., McDiarmid, M., … Utell, M. (1996). Respiratory protection guidelines. This official statement of the American Thoracic Society was adopted by the ATS Board of Directors, March 1996. 154 (4 Pt 1): 1153-65. https://doi.org/10.1164 / ajrccm.154.4.8887621 Henríquez, m; (2012). climatología ambiental de colombia: ediciones usta. Hernández-Ceballos, M. A., H. García-Mozo, J. A. Adame, E. Domínguez-Vilches, J. P. Bolívar, B. A. De la Morena, R. Pérez-Badía, and C. Galán. 2011. Determination of potential sources of Quercus airborne pollen in Cordoba city (southern Spain) using backtrajectory analysis. Aerobiologia 27: 261-276. Hopke, P. K., Xie, Y., Raunemaa, T., Biegalski, S., Landsberger, S., Maenhaut, W., ... & Cohen, D. (1997). Characterization of the Gent stacked filter unit PM10 sampler. Aerosol Science and Technology, 27(6), 726-735. Jaenicke, R. (1980). Atmospheric aerosols and global climate. Journal of Aerosol Science, 11(5–6), 577–588. https://doi.org/10.1016/0021-8502(80)90131-7 Koçak, M., Mihalopoulos, N., & Kubilay, N. (2007). Contributions of natural sources to high PM10 and PM2. 5 events in the eastern Mediterranean. Atmospheric Environment, 41(18), 3806-3818. Montoya et al. INEGI; Instituto Nacional de Estadística, Geografía e Informática, (2007). 1er Informe de la calidad del Aire, México Tabasco. Maenhaut, W., Francois, F., Cafmeyer, J., & Okunade, O. (1995). Atmospheric aerosol studies using the'Gent'stacked filter unit and other aerosol collectors, with multi-elemental analysis of the samples by nuclear-related analytical techniques. Appendix 4 (No. NAHRES--26) Mateo, M. M. (2015). Evaluación de efectos agudos en la función pulmonar por exposición a material par5ticulado fino (pm 2.5) en niños que viven próximos a una playa masivamente contaminada con relaves mineros, Chañaral, Chile. Matus C., P., & Lucero CH., R. (2002). Norma Primaria de calidad del aire. Revista Chilena de Enfermedades Respiratorias, 18(2), 112–122. https://doi.org/10.4067/S071773482002000200006 MiniAmbiente. (2019). MiniAmbiente. Obtenido de Contaminación Atmosférica: http://www.minambiente.gov.co/index.php/asuntos-ambientales-sectorial-yurbana/gestion-del-aire/contaminacion-atmosferica, Moreno, S., Alcalde, R., Distrital, S., Directivos, A., Antonio, J., Escalante, N., … Osorio, B. (2010). Plan Decenal de Descontaminación del Aire para Bogotá. Retrieved from http://ambientebogota.gov.co/en/c/document_library/get_file?uuid=b5f3e23f-9c5f-40ef912a-51a5822da320&groupId=55886 MAVDT. (2010). Protocolo para el monitoreo y seguí miento de la calidad del aire. Ministerio de Ambiente, Vivienda y Desarrollo Territorial, Colombia. Levy, J., Spengler, J.D., Hlinka, D., Sullivan,D., Moon, D.. (2002). Using CALPUFF to evaluate the impacts of power plant emissions in Illinois: model sensitivity and implications, Atmospheric Environment, Volume 36, Issue 6, February 2002, Pages 1063-1075. Ordoñez-Sánchez, Y. C., Reinosa-Valladares, M., Hernández-Garces, A., & CancianoFernández, J. (2018). Aplicación de modelos simplificados para la dispersión de contaminantes atmosféricos. Caso de estudio. Revista Cubana de Química, 30(1), 90-103. OMS. (2005). Organización mundial de la salud. Recuperado el 13 de 03 de 2019, de Guías de calidad del aire de la OMS relativas al material particulado, el ozono, el dióxido de nitrógeno y el dióxido de azufre: https://apps.who.int/iris/bitstream/handle/10665/69478/WHO_SDE_PHE_OEH_0 6.02_spa.pdf?sequence=1 Organización Mundial de la Salud. (2018, mayo). Calidad del aire y salud: Datos y cifras. Recuperado de https://www.who.int/es/news-room/fact-sheets/detail/ambient-(outdoor)air-quality-and-health Pachón, J. E., & Sarmiento Vela, H. (2008). Análisis espacio-temporal de la concentración de metales pesados en la localidad de Puente Aranda de Bogotá-Colombia. In Rev. Fac. Ing. Univ. Antioquia N.° (Vol. 43). Peralta Quispe, J. L. (2017). Determinación del nivel de riesgo de la calidad de aire por material particulado PM10 en los 5 sectores del distrito de Morales - San Martín 2017 (Universidad Peruana Unión ). Retrieved from http://repositorio.upeu.edu.pe/bitstream/handle/UPEU/1188/Jorge_tesis_Titulo_2017.pdf? sequence=5&isAllowed=y Perrone, M. R., Vecchi, R., Romano, S., Becagli, S., Traversi, R., & Paladini, F. (2019). Weekly cycle assessment of PM mass concentrations and sources, and impacts on temperature and wind speed in Southern Italy. Atmospheric Research, 218, 129–144. https://doi.org/10.1016/j.atmosres.2018.11.013 Pineda Ballesteros, D. Y., & Álvarez Rodríguez, S. J. (2015). Evaluación del comportamiento de las concentraciones de pm 10 con relación a variables meteorológicas en tres sedes de la universidad distrital (Universidad Distrital Francisco José de Caldas). Retrieved from http://hdl.handle.net/11349/4711 Piñera, I., Pérez, G., Aldape, F., Flores, J., Molina, E., Ramos, M., … Guibert, R. (n.d.). Estudio de Partículas Finas de la Atmósfera en Centro Habana. Préndez, M., & Calderón, V. (2013). Análisis de contaminantes en la cuenca del río aconcagua en Chile. Evaluación de riesgo humano y ambiental (Universidad de Chile). https://doi.org/10.4067/S0718-07642013000100002 Ramírez, O., Sánchez de la Campa, A. M., Amato, F., Catacolí, R. A., Rojas, N. Y., & de la Rosa, J. (2018). Chemical composition and source apportionment of PM10at an urban background site in a high–altitude Latin American megacity (Bogota, Colombia). Environmental Pollution, 233, 142–155. https://doi.org/10.1016/j.envpol.2017.10.045 Regalado Contreras, A. D. (2015). Caracterización del material particulado del aire ambiente en la ciudad de loja (universidad nacional de loja). Retrieved from http://dspace.unl.edu.ec/jspui/bitstream/123456789/11108/1/Tesis Anabel Regalado_ Lista.pdf Robayo-Avendaño, A., & Galindo-Mendoza, M. G. (2014). Análisis de la probabilidad de dispersión de polen de maíz genéticamente modificado usando el modelo HYSPLIT. Agrociencia, 48(5), 511-523. Rojano, R. E., Arregoces, H. A., Angulo, L. C., & Restrepo, G. M. (2018). Análisis y Origen de las Concentraciones de TSP y PM10 en Minería de Carbón a Cielo Abierto usando Gráficos Polares. Información tecnológica, 29(6), 131-142. Rugeles Ahumada, S. R., & Silva Tibabija, A. S. (2017). Estimación de la contribución de las fuentes emisoras de material particulado pm10 empleando modelos receptores en la zona atmosférica de la universidad de la costa cuc. (Universidad de la costa. ). Retrieved from http://repositorio.cuc.edu.co/bitstream/handle/11323/342/1044429575 - 1140871213.pdf?sequence=1&isAllowed=y Salomon Salomon, A. V. aleria. (2016). Máster en Salud Pública Especialidad en Medicina Preventiva Escuela Nacional de Sanidad Instituto de Salud Carlos III Efecto a corto plazo del material particulado ( PM 2 . 5 y PM 10 ) sobre la mortalidad diaria en España. In masterThesis. Retrieved from http://repositorio.educacionsuperior.gob.ec/handle/28000/4179 Salinas Vio, P. A. (2012). Contaminación atmosférica por material particulado y consultas de urgencias por mornilidad respiratoria en menores de 5 años en la ciudad de Valdivia, período mayo-julio, año 2010. Universidad Austral de Chile. Scire, J. S., Strimaitis, D. G., & Yamartino, R. J. (2000). A user’s guide for the CALPUFF dispersion model. Earth Tech, Inc. Concord, MA, 10. SIAC. (2010). Manual de diseño de sistemas de vigilancia de la calidad del aire. Retrieved August 21, 2018, fromhttp://www.minambiente.gov.co/images/AsuntosambientalesySectorialyUrbana/pdf/ aire/res_2154_021110_manual_operacio.pdf Valdivia, S. A. P. (2016). Analisis Temporal Y Espacial De La Calidad Del Aire Determinado Por Material Particulado Pm 10 Y Pm 2 , 5 En Lima Metropolitana. Anales Científicos, 77(2), 273–283. https://doi.org/10.21704/ac.v77i2.699 Vernette, G. 1985. La plata-forme continentale Caraibe du Colombie (du débouché du Magdalena au golfe de Morrosquillo) Vicéns Moltó, J. L. (2016). Limitaciones de los modelos Gaussianos y dificultades de la CFD en la docencia de la simulación de la dispersión de especies en la atmósfera. Vidal Ros, I., López Lee, R., Cuesta Santos, O. A., Bolufé Torres, J., & García Valdés, E. (2018). Condiciones meteorológicas que influyen en las inmisiones de contaminantes atmosféricos en dos localidades de La Habana Meteorological conditions that influence the immissions of air pollutants in two localities of Havana. In Revista Cubana de Meteorología (Vol. 24). Retrieved from http://rcm.insmet.cu/index.php/rcm/article/view/421/482 Vivar Martínez, E. F. (2014). cuantificación de material particulado pm10 y su efecto toxicológico-ambiental, en la ciudad de azogues (Universidad de cuenca). Retrieved from file:///C:/Users/pc/Downloads/cuantificacion de material particulado pm 10 y su efecto toxicologico a,biental, en la ciudad de azogues..pdf Yuquilema Vilema, R. C. (2018). Material particulado en el área de empaque de harina en industrias molineras y su relación con la afectación a la salud de los trabajadores. Universidad Técnica de Ambato. Facultad de Ingeniería En Sistemas, Electrónica e Industrial. Maestría En Seguridad e Higiene Industrial y Ambiental. Retrieved from http://repositorio.uta.edu.ec/jspui/handle/123456789/28493 Zamarreño, R. A., Gonzalez, P. N., Hanshing, E. X., Amar, G. A., & Pizarro, C. M. (2013). Evaluación del riesgo ambiental por la presencia de mercurio en relaves mineros dentro de la ciudad de andacollo, Chile. Avances En Ciencias e Ingeniería, 4(4), 75–83. Retrieved from http://search.ebscohost.com/login.aspx?direct=true&db=fap&AN=95009271&lang=es Zhang, Z. H., Hu, M. G., Ren, J., Zhang, Z. Y., Christakos, G., & Wang, J. F. (2017). Probabilistic assessment of high concentrations of particulate matter (PM 10 ) in Beijing, China. Atmospheric Pollution Research, 8(6), 1143–1150. https://doi.org/10.1016/j.apr.2017.04.006 Zurrita, A. A., Badii, M. H., Guillen, A., Lugo Serrato, O. L., & Aguilar Garnica, J. J. (2015). Factores Causantes de Degradación Ambiental. Daena: International Journal of Good Conscience, 10(3), 1-9.spa
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1fspa
dc.type.contentTextspa
dc.type.driverinfo:eu-repo/semantics/bachelorThesisspa
dc.type.redcolhttp://purl.org/redcol/resource_type/TPspa
dc.type.versioninfo:eu-repo/semantics/acceptedVersionspa
dc.type.coarversionhttp://purl.org/coar/version/c_ab4af688f83e57aaspa
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2spa


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-ShareAlike 4.0 International
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-ShareAlike 4.0 International