dc.description.abstractMeeting passive and active protection requirements in buildings has brought about demands for new systems, materials, equipment, and even design requirements like the access to housing units with doors that have a minimum fire-resistance rating of 30 minutes. For existing buildings, though, it is not always possible to adapt them to current government regulations, and normal low-cost doors usually do not comply with compartmentalization requirements. Therefore, this study aimed to evaluate the fire resistance of normal wooden doors and low-cost compensatory measures to increase the protection of existing building elements. The lab tests were performed on real-scale wooden door prototypes. Moreover, three protective solutions were tested while added to the doors: (a) fire-rated gypsum boards, (b) cement boards, (c) steel sheet with polyethylene terephthalate felt, in addition to the reference door. It was noted that only the prototype with cement boards managed to resist for 30 minutes. This result evidences the existence of alternative low-cost solutions that can be used in simpler buildings, although some of the usual options may not be able to meet the requirement.spa
dc.format.mimetypeapplication/pdfspa
dc.language.isoeng
dc.publisherCorporación Universidad de la Costaspa
dc.rightsCC0 1.0 Universalspa
dc.rights.urihttp://creativecommons.org/publicdomain/zero/1.0/spa
dc.sourceRevista de la Construccionspa
dc.subjectFire safetyspa
dc.subjectFire doorspa
dc.subjectExisting buildingsspa
dc.subjectFire resistancespa
dc.subjectDesign requirementsspa
dc.titleAnalysis of the fire resistance of normal wooden doors exposed to fire conditionsspa
dc.typeArtículo de revistaspa
dc.source.urlhttps://scielo.conicyt.cl/scielo.php?script=sci_arttext&pid=S0718-915X2020000200359spa
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.identifier.doiDOI: 10.7764/RDLC.19.2.359spa
dc.identifier.instnameCorporación Universidad de la Costaspa
dc.identifier.reponameREDICUC - Repositorio CUCspa
dc.identifier.repourlhttps://repositorio.cuc.edu.co/spa
dc.relation.referencesABNT NBR 15220-2. (2005). Desempenho térmico de edificações - Parte 2: Métodos de cálculo da transmitância térmica, da capacidade térmica, do atraso térmico e do fator solar de elementos e componentes de edificações. Associação Brasileira de Normas Técnicas (ABNT). https://www.abntcatalogo.com.br/norma.aspx?ID=59664spa
dc.relation.referencesABNT NBR 15281. (2005). Porta corta-fogo para entrada de unidades autônomas e de compartimentos específicos de edificações. Associação Brasileira de Normas Técnicas (ABNT). https://www.abntcatalogo.com.br/norma.aspx?ID=125spa
dc.relation.referencesABNT NBR 15930-2. (2018). Portas de madeira para edificações - Parte 2: Requisitos. Associação Brasileira de Normas Técnicas (ABNT). https://www.abntcatalogo.com.br/norma.aspx?ID=400218spa
dc.relation.referencesABNT NBR 6479. (1992). Portas e vedadores: Determinação da resistência ao fogo. Associação Brasileira de Normas Técnicas (ABNT). https://www.abntcatalogo.com.br/norma.aspx?ID=4161spa
dc.relation.referencesABNT NBR 7190. (1997). Projeto de estruturas de madeira. Associação Brasileira de Normas Técnicas (ABNT). https://www.abntcatalogo.com.br/norma.aspx?ID=3395spa
dc.relation.referencesAsimakopoulou, E., Kolaitis, D., & Founti, M. (2015). Fire safety aspects of PCM - enhanced gypsum plasterboards: An experimental and numerical investigation. Fire Safety Journal, 72, 50-58. doi: https://doi.org/10.1016/j.firesaf.2015.02.004.spa
dc.relation.referencesBabrauskas, V. (2005). Charring rate of wood as a tool for fire investigations. Fire Safety Journal, 40, 528-554. doi: https://doi.org/10.1016/j.firesaf.2005.05.006spa
dc.relation.referencesBrentano, T. (2015). A proteção contra incêndios no projeto de edificações, p. 640, Porto Alegre: Author’s edition.spa
dc.relation.referencesCarlo, U., Seito, A., Gill, A., Pannoni, F., Ono, Rosaria, Silva, S., Carlo, U., & Silva, V. (2008). A segurança contra incêndio no brasil, p. 496, São Paulo: Projeto Editora.spa
dc.relation.referencesCruz, H., Nunes, L. (2005). A madeira como material de construção. Núcleo de Estruturas de Madeira, LNEC, p. 27, Lisboa.spa
dc.relation.referencesEN ISO 11925-2. (2010). Reaction to fire tests: Ignitability of building products subjected to direct impingement of flame: Part 2: Single-flame source test. European Standard and International Organization for Standardization (EN ISO).spa
dc.relation.referencesFaccio, H., & Silva, A. (2016). As características de reação ao fogo dos materiais de acabamento e de revestimento diante da ABNT NBR 15.575:2013. Revista Téchne, 232, 1-8. doi: https://doi.org/10.1016/j.firesaf.2015.02.004.spa
dc.relation.referencesGil, A., Pacheco, F., Christ, R., Bolina, F., Khayat, K. H., & Tutikian, B. (2017). Comparative study of concrete panels’ fire resistance. ACI Materials Journal, 114 (5), doi: https://doi.org/10.14359/51689715spa
dc.relation.referencesGwynne, S., & Boyce, K. (2016). Engineering data. In: SFPE Handbook of Fire Protecting Engineering, fifth ed. Springer, pp. 2429–2551.spa
dc.relation.referencesISO 834-1. (1999). Fire-resistance tests - Elements of building construction - Part 1: General requirements. International Organization for Standardization (ISO).spa
dc.relation.referencesIzydorczyka D., Sędłaka B., Papisa B., & Turkowskia P. (2017). Doors with specific fire resistance class. Fire Research Department of Building Research Institute. Procedia Engineering, 172, 417-425. doi: https://doi.org/10.1016/j.proeng.2017.02.010spa
dc.relation.referencesKNAUF. (2018). FIB01 .de Knauf Fireboard Systems. Knauf Fireboard Systems Fire Resistance with Premium Drywalling.spa
dc.relation.referencesOno, R. (2002). Reabilitação sustentável de edifícios na região central da cidade de São Paulo com ênfase na segurança contra incêndio. In NUTAU: sustentabilidade, arquitetura, desenho urbano (pp. 200-210). São Paulo: Universidade de São Paulo.spa
dc.relation.referencesPacheco, F., Christ, R., Quinino, U., & Tutikian, B. F. (2018). Effects of fiber hybridization in advanced cementitious composites durability in humid and aggressive environments. Revista Materia, 23. doi: https://doi.org/10.1590/s1517-707620180003.0505.spa
dc.relation.referencesPinto, E., Calil, C. (2002). Ensaios para avaliação do comportamento de materiais expostos ao fogo: Resistência e Reação. Revista Madeira Arquitetura e Engenharia, 9, 1-10. doi: https://doi.org/10.1016/j.firesaf.2015.02.004.spa
dc.relation.referencesPurser, D. (2000). Toxic product yields and hazard assessment for fully enclosed design fires. Polym. Int. 49, 1232–1255.spa
dc.relation.referencesSilva, C. (2010). Avaliação da resistência ao fogo de produtos de construção. Aveiro: Universidade de Aveiro.spa
dc.relation.referencesTroitzsch, J. (1983). Methods for the fire protection of plastics and coatings by flame retardant and intumescent systems. Progress in Organic Coatings, 11, 41-69. doi: https://doi.org/10.1016/0033-0655(83)80003-Xspa
dc.relation.referencesVargas, M., & Silva, V. (2005). Resistência ao Fogo das Estruturas de Aço, p. 72, Rio de Janeiro: IBS/CBCA. doi: https://doi.org/10.13140/2.1.3361.7926spa
dc.type.coarhttp://purl.org/coar/resource_type/c_6501spa
dc.type.contentTextspa
dc.type.driverinfo:eu-repo/semantics/articlespa
dc.type.redcolhttp://purl.org/redcol/resource_type/ARTspa
dc.type.versioninfo:eu-repo/semantics/acceptedVersionspa
dc.type.coarversionhttp://purl.org/coar/version/c_ab4af688f83e57aaspa
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2spa


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

  • Artículos científicos [3120]
    Artículos de investigación publicados por miembros de la comunidad universitaria.

Mostrar el registro sencillo del ítem

CC0 1.0 Universal
Excepto si se señala otra cosa, la licencia del ítem se describe como CC0 1.0 Universal