Identification and quantification of microplastics in effluents of wastewater treatment plant by differential scanning calorimetry (DSC)
Artículo de revista
2022-04-20
MDPI AG
Sustainability
14
9
1
10
2071-1050
In this research, the presence of microplastics was detected through a differential scanning calorimetry (DSC) analysis of three wastewater treatment plants. One of these plants applied only a preliminary treatment stage while the others applied up to a secondary treatment stage to evaluate their effectiveness. The results showed the presence of polyethylene (PE), polystyrene (PS), polypropylene (PP) and polyethylene terephthalate (PET), which were classified as fragments, fibers or granules. During the evaluation of the plants, it was determined that the preliminary treatment did not remove more than 58% of the microplastics, while the plants applying up to a secondary treatment with activated sludge achieved microplastic removal effectiveness between 90% and 96.9%.
- Artículos científicos [3095]
Descripción:
Identification and Quantification of Microplastics in Effluents of Wastewater Treatment Plant by Differential Scanning Calorimetry (DSC).pdf
Título: Identification and Quantification of Microplastics in Effluents of Wastewater Treatment Plant by Differential Scanning Calorimetry (DSC).pdf
Tamaño: 812.5Kb
PDFLEER EN FLIP
Título: Identification and Quantification of Microplastics in Effluents of Wastewater Treatment Plant by Differential Scanning Calorimetry (DSC).pdf
Tamaño: 812.5Kb
PDFLEER EN FLIP